Tricor Mass TCM0325

  • Type:Mass Flowmeter
  • Medium:Liquid or Gas
  • Mass Flow Rate (max.): 325 kg/h[12 lb/min]
  • Nominal Meter Size: DN4 [1/8”]
  • Accuracy:±0.1% M.V.
  • Max. Temperature:-60…200℃
  • Max. Pressure:345bar
  • Warranty:1 year warranty

TRICOR Coriolis mass flow meters for liquids and gases.

The TRICOR CLASSIC Series TCM 0325 Coriolis Mass Flow Meter has a maximum mass flow rate of 325 kg/hr (12 lb/min) or 49 bbl/day and nominal size of DN4 (1/8”), and is rated for process pressures up to 200 bar (2900 psi). Standard accuracy for the TCM 0325 is 0.3%, but with a custom calibration, 0.1% accuracy is possible. The diamond shape (D-shape) tube design has the best overall performance of any Coriolis tube shape. The mechanical advantages of this design include the best signal-to-noise ratio and reduced effects of external vibrations, thus improving zero stability.

Features & Benefits

  • Robust, no moving parts for long life
  • Custom flow connectors & installation lengths
  • Excellent repeatability (±0.05 % of flow rate)
  • High pressure option: 345 bar [5,000 psi]
  • Increased productivity, lower maintenance
  • Lower installation cost
  • Increased product quality
  • Broad applications: dosing, paint, chemical injection

Functions & Specifications

Flow Rate
Mass Flow Rate (max.): 325 kg/h [12 lb/min]
Volumetric Flow Rate (max.): 325 l/h [1.43 gpm, 49 oil bbl/d (US)]
Nominal Meter Size: DN4 [1/8”]
Pressure Rating
200 bar [2,900 psi]
Option: up to 345 bar [5,000 psi]
Accuracy (Liquids)
Basic Accuracy (Mass Flow): ±0.3 % (option: up to ±0.1 %) of flow rate
Repeatability (Mass Flow): ±0.05 % of flow rate
Basic Accuracy (Volume Flow): ±0.3 % (option: up to ±0.15 %) of flow rate
Repeatability (Volume Flow): ±0.05 % of flow rate
Zero Stability: ±0.01 % of full scale
Accuracy (Gases)
Basic Accuracy (Mass Flow): ±1 % (option: up to ±0.5 %) of flow rate
Repeatability (Mass Flow): ±0.25 % of flow rate
Density
Density Range: up to 2,500 kg/m3 [2.5 g/cm3]
Density Accuracy: ±1.0 kg/m3 [±0.001 g/cm3]
Density Repeatability: ±0.5 kg/m3 [±0.0005 g/cm3]
Temperature
Process Temperature Range: -40 °C … +100 °C [-40 °F … +212 °F]
Option:-60 °C … +200 °C [-76 °F … +392 °F]
Temperature Accuracy: ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]
Temperature Repeatability: ±0.2 °C [±0.36 °F]
Materials (Wetted Parts)
Tubes: 1.4404 [AISI 316L]
Case: 1.4404 [AISI 316L]
Flow Splitter: 1.4404 [AISI 316L]
Brazing Alloy: BNi-2
滚动至顶部