TRICOR Coriolis mass flow meters for liquids and gases.
The TRICOR CLASSIC Series TCM 7900 Coriolis Mass Flow Meter has a maximum mass flow rate of 7900 kg/hr (290 lb/min) or 1193 bbl/day and nominal size of DN15 (1/2”), and is rated for process pressures up to 100 bar (1450 psi). Standard accuracy for the TCM 7900 is 0.3%, but with a custom calibration, 0.1% accuracy is possible. These meters have good overall accuracy, zero stability, and pressure drop. The simple self-draining U-shape tube design provides for easy cleaning/flushing.
Features & Benefits
- Robust, no moving parts for long life
- Custom flow connectors & installation lengths
- Excellent repeatability (±0.05 % of flow rate)
- Optional Net Oil functionality
- Increased productivity, less maintenance
- Lower installation cost
- Increased product quality
- Simpler whole solution for Net Oil without PLC/RTU
Functions & Specifications
Flow Rate
Mass Flow Rate (max.): 7,900 kg/h [290 lb/min]
Volumetric Flow Rate (max.): 7,900 l/h [34.78 gpm, 1,193 oil bbl/d (US)]
Nominal Meter Size: DN15 [1/2”]
Volumetric Flow Rate (max.): 7,900 l/h [34.78 gpm, 1,193 oil bbl/d (US)]
Nominal Meter Size: DN15 [1/2”]
Pressure Rating
100 bar [1,450 psi]
Accuracy (Liquids)
Basic Accuracy (Mass Flow): ±0.3 % (option: up to ±0.1 %) of flow rate
Repeatability (Mass Flow): ±0.05 % of flow rate
Basic Accuracy (Volume Flow)2): ±0.3 % (option: up to ±0.15 %) of flow rate
Repeatability (Volume Flow): ±0.05 % of flow rate
Zero Stability: ±0.01 % of full scale
Repeatability (Mass Flow): ±0.05 % of flow rate
Basic Accuracy (Volume Flow)2): ±0.3 % (option: up to ±0.15 %) of flow rate
Repeatability (Volume Flow): ±0.05 % of flow rate
Zero Stability: ±0.01 % of full scale
Accuracy (Gases)
Basic Accuracy (Mass Flow): ±1 % (option: up to ±0.5 %) of flow rate
Repeatability (Mass Flow): ±0.25 % of flow rate
Repeatability (Mass Flow): ±0.25 % of flow rate
Density
Density Range: up to 2,500 kg/m3 [2.5 g/cm3]
Density Accuracy: ±1.0 kg/m3 [±0.001 g/cm3]
Density Repeatability: ±0.5 kg/m3 [±0.0005 g/cm3]
Density Accuracy: ±1.0 kg/m3 [±0.001 g/cm3]
Density Repeatability: ±0.5 kg/m3 [±0.0005 g/cm3]
Temperature
Process Temperature Range: -40 °C … +100 °C [-40 °F … +212 °F]
Option:
-60 °C … +200 °C [-76 °F … +392 °F]
Temperature Accuracy: ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]
Temperature Repeatability: ±0.2 °C [±0.36 °F]
Option:
-60 °C … +200 °C [-76 °F … +392 °F]
Temperature Accuracy: ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]
Temperature Repeatability: ±0.2 °C [±0.36 °F]
Materials (Wetted Parts)
Tubes: 1.4404 [AISI 316L]
Case: 1.4404 [AISI 316L]
Flow Splitter: 1.4404 [AISI 316L]
Brazing Alloy: BNi-2
Case: 1.4404 [AISI 316L]
Flow Splitter: 1.4404 [AISI 316L]
Brazing Alloy: BNi-2